                                                                            Page 58 of 58                   Report No. JSH006100256-002 
IEC 60825-1 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
Appendix no. 2 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Details of measurement procedure and measurement results: 
 
Step 
 
specified / measured / calculated
 
unit
 
Classification, Laser Class 
----- 
Typical wavelength of laser diode 
λ
 = 790 (CD) 
λ
 = 650 (DVD) 
nm  
nm 
Emission duration 
t = ∞ 
Time basis 
T = 100 
s  
Size of apparent source  
-- 
mm 
Angular subtense 
 <1.5  
mrad 
Limiting angular subtense 
α
min 
= 1.5;  
α
max 
= 100 
mrad  
mrad 
Angle of acceptance 
γ
= N/A 
mrad 
Diameter of aperture stop 
d = 7 (for Class 1) 
mm 
Distance of aperture stop to source 
r = 14 (for Class 1) 
mm 
 
 
 
Calculation of AEL 
(Class as above) : 
(Radiant Power 
[
W]
 
Used formula 
(CD)Class 1: 3.9 x 10
-4
 C
4
C
7
 
(DVD)Class 1: 3.9 x 10
-4
 
Used correction factors 
C
4
=10
0.002(
λ
-700)
=1.51 
C
7
=1 
 
Accessible emission limit 
(CD)Class 1: AEL
radiant 
= 0.589 
(DVD)Class 1: AEL
radiant 
= 0.390 
mW 
mW 
 
 
 
Measurement results: 
 
Class 1  
 
Normal condition 
(CD)Pm
 
= 0.134 
(DVD) Pm
 
= 0.173 
mW 
mW 
Abnormal condition: Max. output power
(CD)Pm
 
= 0.250 
(DVD) Pm
 
= 0.380 
mW 
mW 
 
 
 
 
 
 