                                                                                Page 26 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Operating conditions 
PCB near IC1 
52.3 
33.5 
75 
EC1 (electrolytic capacitor) 
18.5 
14.6 
70 (105-35) 
Winding of TR1 
23.9 
16.7 
65* 
Bobbin of TR1 
21.7 
16.1 
65 
PCB near TR1 
20.7 
16.5 
75 
CY1 (Y1 capacitor)  
15.0 
13.6 
50 (85-35) 
CY3 (Y1 capacitor)  
21.4 
17.7 
50 (85-35) 
PCB near IC3 
11.9 
10.0 
75 
PCB near D15 
22.8 
19.7 
75 
EC19 (electrolytic capacitor) 
15.2 
13.3 
70 (105-35) 
Power cord 
10.3 
8.8 
50  
Enclosure (metallic)  
9.9 
7.5 
30  
Enclosure (non-metallic) 
4.9 
3.8 
50 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation 
100 
Between parts separated by double or reinforced insulation 
100 
Between parts of TR1 separated by basic or supplementary 
insulation 
100 2 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Page of 60