Read Harman Kardon HD 950 (serv.man3) EMC - CB Certificate online
Page 23 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
Pass
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
Pass
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT used.
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A