www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.4.3 
Connection of limited current circuits to other 
circuits 
Output circuit of the external 
power supply connected to 
primary in the external power 
supply via one bridging 
capacitor. 
 
2.5 
Limited power sources 
 Inherently 
limited 
output 
 
N/A 
 Impedance 
limited 
output 
 
N/A 
 
Overcurrent protective device limited output 
 
N/A 
 
Regulating network limited output under normal 
operating and single fault condition 
USB, in and output signals. 
(The USB port does not provide 
5Vdc voltage output) 
 
Regulating network limited output under normal 
operating conditions and overcurrent protective 
device limited output under single fault condition 
 
N/A 
 
Output voltage (V), output current (A), apparent 
power (VA) .........................................................: 
See summary of testing and 
appended table 4.3.8. 
— 
 
Current rating of overcurrent protective device (A)  
— 
 
2.6 
Provisions for earthing and bonding 
N/A 
2.6.1 
Protective earthing 
Class III equipment. 
N/A 
2.6.2 Functional 
earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG....................................................................: 
 
— 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG....................................................................: 
 
— 
2.6.3.4 
Resistance (
Ω) of earthing conductors and their 
terminations, test current (A)...............................: 
 
N/A 
2.6.3.5 
Colour of insulation .............................................:   
N/A 
2.6.4 Terminals 
 
N/A 
2.6.4.1 General 
 
N/A 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 