Read Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate online
- Page 15 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2.2.2
Voltages under normal conditions (V).................: Powered by SELV source.
P
2.2.3
Voltages under fault conditions (V) .....................: Powered by SELV source.
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
N/A
2.2.3.2
Separation by earthed screen (method 2)
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
N/A
2.2.4
Connection of SELV circuits to other circuits....... : SELV circuits are only
connected to other SELV
circuits and protective earth.
circuits and protective earth.
P
2.3 TNV
circuits
N/A
2.3.1 Limits
No
TNV
circuits.
N/A
Type of TNV circuits............................................:
—
2.3.2
Separation from other circuits and from
accessible parts
accessible parts
N/A
Insulation
employed ............................................:
—
2.3.3
Separation from hazardous voltages
N/A
Insulation
employed ............................................:
—
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation
employed ............................................:
—
2.3.5
Test for operating voltages generated externally
N/A
2.4 Limited
current
circuits
P
2.4.1
General requirements
Bridging capacitor (Y1) across
insulation in the specified
external power supply (See
copy of marking plate).
insulation in the specified
external power supply (See
copy of marking plate).
P
2.4.2 Limit
values
49mA,
73.7nF
P
Frequency
(Hz) ................................................... :
70kHz
—
Measured current (mA) ....................................... : 1.8mA peak
—
Measured voltage (V).......................................... : 610Vp
—
Measured capacitance (
µF) ................................ : 3300pF
—
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.