Read Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate online
- Page 13 of 58 -
www.nemko.com
Report No. 70512
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.7.1
Protective earthing and bonding terminals ........ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Refer below:
P
1.7.8.1
Identification, location and marking ................... : No controls or figures affecting
safety provided.
N/A
1.7.8.2
Colours ............................................................... : No controls or indicators us
color.
N/A
1.7.8.3
Symbols ............................................................ : There are no switches in the
equipment. Control is marked
with “+” and “-“.
with “+” and “-“.
P
1.7.8.4
Markings using figures ...................................... : Refer to Copy of marking, the
manufacturer includes
explanation of graphic symbols
in the instruction manual.
explanation of graphic symbols
in the instruction manual.
P
1.7.9
Isolation of multiple power sources .................... : Class III equipment.
N/A
1.7.10
IT power distribution systems
Class III equipment.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12
Language ........................................................... : Instructions and markings shall
be in a language acceptable for
the country where the
equipment is to be sold.
English manual verified.
the country where the
equipment is to be sold.
English manual verified.
—
1.7.13 Durability
The
marking withstands
required tests.
P
1.7.14
Removable parts
No removable parts, except
batteries.
batteries.
P
1.7.15
Replaceable batteries
Normal D-cell batteries to be
used in the equipment.
(See summary of testing).
used in the equipment.
(See summary of testing).
P
Language ............................................................ :
—
1.7.16
Operator access with a tool ................................ : No hazardous voltages or
energy levels in the equipment
in normal or single fault
condition.
(See appended table 5.3)
in normal or single fault
condition.
(See appended table 5.3)
P
1.7.17
Equipment for restricted access locations .......... : Equipment not intended for
installation in RAL.
N/A
Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.