GO AND PLAY (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon GO AND PLAY (serv.man4) EMC - CB Certificate online

 
 
- Page 13 of 58 - 
 
 
www.nemko.com
 
Report No.  70512 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
1.7.7.1 
Protective earthing and bonding terminals  ........ :   
N/A 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
Refer below: 
1.7.8.1 
Identification, location and marking  ................... :  No controls or figures affecting 
safety provided. 
N/A 
1.7.8.2 
Colours ............................................................... :  No controls or indicators us 
color. 
N/A 
1.7.8.3 
Symbols   ............................................................ :  There are no switches in the 
equipment. Control is marked 
with “+” and “-“.  
1.7.8.4 
Markings using figures   ...................................... :  Refer to Copy of marking, the 
manufacturer includes 
explanation of graphic symbols 
in the instruction manual. 
1.7.9 
Isolation of multiple power sources .................... :  Class III equipment. 
N/A 
1.7.10 
IT power distribution systems  
Class III equipment. 
N/A 
1.7.11 
Thermostats and other regulating devices  
No thermostats or other 
regulating devices.  
N/A 
1.7.12 
Language  ........................................................... :  Instructions and markings shall 
be in a language acceptable for 
the country where the 
equipment is to be sold. 
English manual verified. 
— 
1.7.13 Durability 
The 
marking withstands 
required tests. 
1.7.14 
Removable parts 
No removable parts, except 
batteries. 
1.7.15 
Replaceable batteries 
Normal D-cell batteries to be 
used in the equipment.  
(See summary of testing). 
 Language ............................................................ : 
 
— 
1.7.16 
Operator access with a tool ................................ :  No hazardous voltages or 
energy levels in the equipment 
in normal or single fault 
condition.  
(See appended table 5.3) 
1.7.17 
Equipment for restricted access locations .......... :  Equipment not intended for 
installation in RAL.  
N/A 
 
Page of 127
Display

Click on the first or last page to see other GO AND PLAY (serv.man4) service manuals if exist.