Read Harman Kardon DVD 506 (serv.man12) EMC - CB Certificate online
page 5 of 40
Ref.No.: JHS0311045-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
7
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
Mating locking connector, no
supportive function
supportive function
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Not used.
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class
Ι equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
Class II
N
Capacitors bridging basic insulation complying with
14.2.1a
14.2.1a
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
Class
ΙΙ
equipment and Class
ΙΙ
constructions
within Class
Ι
equipment
N
8.6
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
TR1
P
Click on the first or last page to see other DVD 506 (serv.man12) service manuals if exist.