Read Harman Kardon DVD 506 (serv.man12) EMC - CB Certificate online
page 7 of 40
Ref.No.: JHS0311045-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
8.11
Detaching of wires
No undue reduction of creepage or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached.
detached.
P
Vibration test carried out ................................... : No, no need. See above.
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No socket-outlet
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (pull test 50 N, for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Internal wires secured and
keep enough distance from
sharp or hot parts
keep enough distance from
sharp or hot parts
P
8.16
Only special supply equipment can be used
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1.1
Touch current measured from terminal devices
using the network in Annex D: ............................
using the network in Annex D: ............................
U1= 0.45 Vp
U2= 0.15 Vp
P
Discharge not exceeding 45
µ
C
P
Energy of discharge not exceeding 350 m J
N
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
< 2 mm, no entering
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe 16 of IEC 61032
pin (10 N); test probe 16 of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1N); test probe D of IEC 61032
straight wire (1N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s:
withdrawal of the mains plug; voltage (V) after 2 s:
N
If C is not greater than 0.1
µ
F no test needed
0.1
µ
F
P
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P