Read Harman Kardon DVD 506 (serv.man12) EMC - CB Certificate online
page 6 of 40
Ref.No.: JHS0311045-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
CY1, CY2, CY3
P
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
N
Reinforced or double insulation between circuits
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
N
Separation by Class
ΙΙ
isolating transformer
N
Separation by Class
Ι
transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation
≥
0.4 mm (mm) :
N
Reinforced insulation
≥
0.4 mm (mm) ................. : TR1 bobbin: 1mm
Optocoupler PH1: 0.45mm
Separation sheet on internal
enclosure above power PCBA:
enclosure above power PCBA:
0.5mm
P
Thin sheet insulation
Inside TR1
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Live wires are double
insulated. Basic insulated sec.
wires cannot reach closer than
3 mm from live parts.
insulated. Basic insulated sec.
wires cannot reach closer than
3 mm from live parts.
P