DVD 506 (serv.man12) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon DVD 506 (serv.man12) EMC - CB Certificate online

 
 
page 8 of 40 
Ref.No.: JHS0311045-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
30 mm diameter test tool for 5 s (100 or 250 N): ...   100N 
9.2 
No hazard after removing a cover by hand 
Tools required 
 
10 
INSULATION REQUIREMENTS  
 
 
(See appended table) 
 
10.1 
Insulation resistance (M
) at least 2 M
 min. after 
surge test for basic and 4 M
 min. for reinforced 
insulation 
> 100 M
 
10.2 
Humidity treatment 48 h or 120 h 
120 h, 40
o
C, 39%  
10.3 
Insulation resistance and dielectric strength 
 
 
11 
FAULT CONDITIONS    
 
 
 
(See appended table) 
 
11.1 
No shock hazard under fault conditions 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of Table 2 by max. 100 K for 
max. 5 min 
 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of Table 2 by not 
more than 100 K for an area not greater than 
2 cm
2
 
 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm
2
 for a maximum of 5 min 
 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of other parts not subject to the 
limits of 11.2.1 to 11.2.5 
 
 
Page of 45