Ref.No.: JHS0311045-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
14.6 
Switches 
 
 
 
 
 
(See appended table) 
14.6.1 
Permanently connected equipment provided with 
an all-pole mains switch unless 5.4.2 is met 
 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required ................. : 
No, measured 14.1W under 
normal condition. 
 
Switch readily accessible and not in mains cord 
 
 
Exception for automatic switching 
 
 
Exception for continuous operation 
 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
 
Indication by marking meets Cl. 5 
 
 
Indication of the OFF position 
OFF 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ......................... : 
 
Yes 
 
Stand-by mode clearly discernible ...................... :  Illumination 
 
Exception for low Stand-by current < 0.7 mA 
(peak) 
 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 