DVD 506 (serv.man12) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 22

Read Harman Kardon DVD 506 (serv.man12) EMC - CB Certificate online

 
 
page 17 of  40 
Ref.No.: JHS0311045-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
16.5 
Adequate strain relief on external flexible cords 
 
 
Not possible to push cord back into equipment 
 
 
Strain relief device unlikely to damage flexible cord   
 
For mains cords of Class 
Ι
 equipment, hazardous 
live conductors become taut before earth 
conductor 
 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to Table 12: 
 
 
- screws into metal: 5 times 
3 mm, 0.5Nm 
 
- screws into non-metallic material: 10 times  
 
17.2 
Correct introduction into female threads in non-
metallic material 
 
17.3 
Cover fixing screws: captive 
 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 
17.4 
No loosening of conductive parts carrying a current 
> 0.2 A 
 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0.2 A 
 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0.2 A with screw terminals not 
consolidated by solder 
 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 
17.8 
Fixing devices for detachable legs or stands 
provided 
 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
 
Page of 45
Display