DVD 506 (serv.man12) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 20

Read Harman Kardon DVD 506 (serv.man12) EMC - CB Certificate online

 
 
page 15 of  40 
Ref.No.: JHS0311045-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
equipment 
 
 
Class 
Ι
 supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 
 
Protective earth conductors correctly coloured 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
 
Protective earth terminal resistant to corrosion 
 
 
Earth resistance (
 0.1 
 at 25 A ................... :   
15.3 
Terminals for external flexible cords and for permanent connection to the mains supply 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 
15.3.2 
Reliable connection of non-detachable cords: 
 
 
not soldered to conductors of a printed circuit 
board 
No 
 
adequate clearances and creepage distances 
between connections should a wire break away 
 
 
wire secured by additional means to the conductor  Mating locking connector. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Mating locking connector, both 
the conductor and insulation 
are crimped. 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 
15.3.6 
Terminals to 15.3.3 have sizes required by Table 8   
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 
 
Page of 45
Display