Test report no. 305945I
Page 12 (12)
 
7.  IMMUNITY TO BURST, EN 61000-4-4 
 
7.1 Operating environment 
 
Temperature: 21 
°C 
Relative Humidity: 
49  % 
 
 
7.2 Test set-up 
 
The EUT was placed on a non-metallic table 0,8 m above a reference ground plane (RGP) and was put into 
operation according to the specified operating mode. 
 
 
7.3 Test conditions 
 
Test level: 
1,0 kV 
AC-power port 
 
Performance criterion: 
 
Repetition rate: 
5 kHz 
 
Application method: 
AC mains - Coupling/decoupling network, (CDN) 
 
Duration of each test: 
1 min 
 
Ports for test: 
AC-power 
 
EUT- position: 
Table top 
 
 
7.4 Measurement uncertainty 
 
The uncertainty of the applied fast transient/burst is within the tolerance specified by the standard. 
 
 
7.5 Test equipment 
 
Equipment 
Manufacturer  
Type 
SEMKO No. 
 
Test generator including CDN:  
Haefely 
PEFT Test system 
5644 
Software: Haefely 
WinPats, 
Version 
3.15 
 
Reference ground plane 
 
Aluminium 4,0 m x 2,5 m x 1,5 mm 
 
 
7.6 Test protocol 
 
Date of test: 10 June, 2003 
 
Test 
No. 
Level 
[kV] 
Polarity 
+/- 
Line/Cable Coupling 
Device 
 
Pass/
Fail 
Comment 
1 1  + 
AC-power 
(L/N
/
) CDN 
Pass  - 
2 1  - 
AC-power 
(L/N
/
) CDN 
Pass Not.1 
 
Not.1  short horizontal rules came up during the test, but the function of the EUT was not disturbed. 