DVD 30 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 22

Read Harman Kardon DVD 30 EMC - CB Certificate online

 
Test report no. 305945I
Page 4 (12)
 
3. TEST 
SPECIFICATIONS 
 
3.1 Standards 
 
EN 55 020 (1994) and Amendments A11(1996), A12(1999), A13(1999) and A14(1999): Electromagnetic 
immunity of broadcast receivers and associated equipment. 
 
The equipment has no external power connection or connection facility for external antenna and therefore 
testing has only been performed according to Amendment A12 (1999). 
 
Amendment A12 refers to the following basic standards: 
 
 
EN 61000-4-2 (1995) and A1(1995):  Electrostatic discharge immunity test. 
 
Required test level: 
Air discharge 8 kV, contact discharge 4 kV. 
 
 
EN 61000-4-3 (1996): 
Radiated, radio-frequency, electromagnetic field immunity test. 
 
Required test level: 
895-905 MHz, 3 V/m, 50 % duty cycle, 200 Hz rep. frequency. 
 
 
EN 61000-4-4 (1995): 
Electrical fast transient/burst requirements. 
 
Required test level: 
1,0 kV AC supply. 
 
 
3.2 Additions, deviations and exclusions from standards and accreditation 
 
No additions, deviations or exclusions have been made from standard. 
All tests performed are within the scope of the accreditation. 
 
 
3.3 Mode of operation during the test 
 
During the test the EUT was operating in the following mode: 
 
The DVD-player was playing a test DVD disc. 
 
 
 
 
Page of 30
Display

Click on the first or last page to see other DVD 30 service manuals if exist.