Report No. JSH05110331-001 
Page 54 of 64 
 
15.2 Block Diagram of Test Setup 
 
 
 
 
15.2.1 Test Setup and Test Procedure 
 
 
Table top EUT 
 
The EUT was placed on a 0.8m high wooded table, standing on the ground reference  
plane 2.6m by 1.8m in size, made by aluminium 0.5mm thick. 
 
The distance between the EUT and any other of the metallic surface except the GRP is  
greater than 0.5m. 
 
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated  
at a distance of 0.1m above the ground reference plane to insure the distance between the  
coupling device and the EUT were 1m or less. 
 
The EUT was arranged and connected to satisfy its functional requirement and supplied by  
The coupling-decoupling network (Best EMC). 
 
 
Floor Standing EUT 
 
The EUT was placed on a 0.1m high wooden support, standing on the ground reference 
plane 2.6m by 1.8m, made by aluminium 0.5mm thick. 
 
The distance between the EUT and any other of the metallic surface except the GRP is  
greater than 0.5m. 
 
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated  
at a distance of 0.1m above the ground reference plane to insure the distance between the  
coupling device and the EUT were 1m or less. 
 
The EUT was arranged and connected to satisfy its functional requirement and supplied by  
The coupling-decoupling network (Best EMC). 
 
Best EMC 
 
     
EUT 
GRP 