Read Harman Kardon DVD 23 (serv.man12) EMC - CB Certificate online
Report No. JSH05110331-001
Page 52 of 64
14.3.3 Photo For Test Set-up
none.
14.4 Test Protocol
Temperature :
23
°C
Relative Humidity:
40%
Direct discharge was applied at the following selected points:
Test point
#
Test level
[kV]
Air/
Contact
Polarity
(+/-)
Pass/
Fail
Comment
A
4
Contact
+/-
P
all touchable screws of
enclosure
enclosure
B
4
Contact
+/-
P
Accessible metal parts of the
EUT
EUT
C
8
Air
+/-
P
Air gap of the switch, button
D
8
Air
+/-
P
The air in-taking opening
E
8
Air
+/-
P
Slots around the EUT
Indirect contact discharges were applied to the VCP and the HCP at the following selected points:
Point Description
Point
Result
HCP f
0,1m from the front of the EUT
Edge of centre,coner on HCP
P
HCP b
0,1m from the back of the EUT
Edge of centre,coner on HCP
P
HCP r
0,1m from the right side of the EUT
Edge of centre,coner on HCP
P
HCP l
0,1m from the left side of the EUT
Edge of centre,coner on HCP
P
VCP f
0,1m from the front of the EUT
Edge of centre,coner on VCP
P
VCP b
0,1m from the back of the EUT
Edge of centre,coner on VCP
P
VCP r
0,1m from the right of the EUT
Edge of centre,coner on VCP
P
VCP l
0,1m from the left of the EUT
Edge of centre,coner on VCP
P
14.5 Additions, Deviations and Exclusions from Standards
None
Click on the first or last page to see other DVD 23 (serv.man12) service manuals if exist.