9. Screening effectiveness (S4)
9.1 Test criteria and test procedure
Operating environment;
Temperature
20 ℃
Relative Humidity
40 %
The equipment under test was placed on a non-metallic table of height 0.8 M.
At the side of the antenna input terminal of the equipment under test, a non-metallic table
of length 4 M was placed at the same height to provide for movement of the measuring
device, an absorbing clamp.
An RF signal generator is placed on a third table.
The equipment under test is connected to the generator, but not connected to the mains supply.
The signal from the generator is at the test frequency and unmodulated.
9.2 Measurement uncertainty
Radiated fields : +/- 2dB
9.3 Test result immunity to conducted voltage.
The equipment does comply with the requirements.
For the measurement data, see Annex E