DPR 1005 (serv.man14) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon DPR 1005 (serv.man14) EMC - CB Certificate online

 
WOORI Technology Inc.                        Page 14 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (EN61000-4-3) 
 
11.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
The tests were performed at 3m distance in an anechoic chamber.   
        For floor-standing equipment, the EuT was mounted non-conducting support 0.1m above the 
        supporting plane. For tabletop equipment, the EuT was located on a wooden table 0.8m above the floor. 
        The EuT was exposed to the field from different angles, normally 0。, 90。,180。,270。, 
        and at both horizontal and vertical polarization(antenna height 1.75m) 
        A signal level of 3V/m, duty cycle 1/8 Pulse modulated with 217Hz sine wave was applied in the   
frequency range 900MHz.   
 
Instrumentation used during this session: 
 
Instruments 
Manufacturer
Model 
Serial Number 
Due to Calibration
Signal Generator
 
R & S
 
SMY01
 
1062.5502.11
 
2004. 12 
Power Amplifier
 
Noiseken
 
NA25MF1G2010C
 
A00518
 
2005. 02 
Power Sensor
 
HP
 
8482A
 
U537293322
 
2005. 04 
Power Sensor
 
HP
 
8482A
 
U537293323
 
2005. 04 
Power Meter
 
HP
 
E4419B
 
GB39511164
 
2005. 04 
Biconical log Antenna
 
ARA
 
LPB-2520/A
 
1180
 
2005. 02 
Selective Level Meter
 
Anritsu
 
ML422B
 
M18572
 
2005. 07 
 
11.2 Test Parameters 
 
 Port: 
Enclosure 
 
Test Engineer: 
J. Y. Yu 
 Basic Standard:  EN 61000-4-3:2002 
 
Performance Criteria: 
 Dwell Time : 
3 Sec 
 Test 
Level 
3 Vrms 
Modulation : 
50% Duty PM @ 200 Hz 
Frequency Range : 
895-905 MHz 
Page of 127