WOORI Technology Inc.                        Page 7 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
5. Input immunity to RF voltages (in Differential mode) (S1) 
 
5.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature 
23  ℃ 
 
Relative Humidity 
40 % 
 
      The criterion concerning acceptable sound interference is a wanted to unwanted   
   audio signal ratio of ≥40 dB at a wanted signal level of 50 mW. 
 
      The EUT was placed 0.1m above a metallic ground plane of dimensions 2 x 1 m. 
      The measuring set-up was shown in Figure 1 EN55020 (2002). 
      The principle of operation was similar to the measuring set-up of Figure 1 EN55020 (2002). 
       
      The low pass filter was added to prevent influence of the measuring results by 
      harmonics of the unwanted signal generators. 
 
      The lineout of the EUT were applied to an 22k ohm purely resistive road (Ro
      and then to the AF inputs of the test system. 
      The power supply of the EUT was connected to a standard voltage source 
   (without special filters). 
   The measurements were performed with test software TS9980 Ver.2.9. 
 
5.2 Measurement uncertainty 
 
    Antenna input immunity +/- 2.0dB 
 
5.3 Test result of input immunity to RF voltages. 
 
        The equipment does comply with the requirements. 
 
    For the measurement data, see Annex A 
 
Page of 127
Display