Read Harman Kardon DPR 1005 (serv.man14) EMC - CB Certificate online
WOORI Technology Inc. Page 6 of 104
DPR 1005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 320.EMS
3. TEST SPECIFICATIONS
3.1 Standards
EN55 020(2002) : Electromagnetic immunity of broadcast receivers and associated equipment.
3.2 Additions, deviations and exclusions from standards
No additions, deviations or exclusions have been made from standard.
3.3 Purpose of the test
Purpose of test: To determine whether the equipment under test fulfils the EMC immunity
requirements of the standard stated in section 3.1
3.4 Test site location
ANAM Electronics Co., Ltd.
Nemko korea Co., Ltd.
3.4.1 Location
645, Sungkok-dong, Ansan-City, Kyungki-Do, 425-110, Korea
This test site has been accredited to EMC TBM (EN 55013, EN55020) test site by Nemko.
The AUT. No. is : 357
4. TEST SUMMARY
The results in this report apply only to sample tested :
Test
Passed the test
Note
Input immunity to RF voltages (S1)
Yes
Immunity to RF voltages (S2a)
Yes
Immunity to RF voltages(in common mode) (S2b)
Yes
Immunity to ambient electromagnetic fields (S3)
Yes
Screening effectiveness (S4)
Yes
Test
Passed the test
Electrostatic Discharge (EN 61000-4-2)
Yes
Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test
(EN 61000-4-3)
Yes
Electrical Fast Transients/Burst (EN 61000-4-4)
Yes
The equipment does comply with the requirements
Measurement data see Annex A, B, C, D and E.
Click on the first or last page to see other DPR 1005 (serv.man14) service manuals if exist.