Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 56 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
SE Sweden
(after the compliance statement)
already part of A11 (This note will be deleted from
the final text)
already part of A11 (This note will be deleted from
the final text)
US United States of America
US
1.1.1
Scope clarification:
The standard also covers commercial and
professional apparatus; professional apparatus
may also be investigated using UL 1419.
Projection apparatus is not covered. Household
games, household gaming and scoring machines,
satellite receiver antenna positioners are covered
by this standard but commercial games and
commercial gaming and scoring machines, and
other types of antenna positioners are covered by
other standard.
professional apparatus; professional apparatus
may also be investigated using UL 1419.
Projection apparatus is not covered. Household
games, household gaming and scoring machines,
satellite receiver antenna positioners are covered
by this standard but commercial games and
commercial gaming and scoring machines, and
other types of antenna positioners are covered by
other standard.
Add: Mains connected apparatus intended for
field installation requires compliance with the
National Electrical Code, ANSI, NFPA 70.
field installation requires compliance with the
National Electrical Code, ANSI, NFPA 70.
P
1.1.3
Protection against splashing water replaced with
apparatus intended for outdoor use (See Annex
A).
apparatus intended for outdoor use (See Annex
A).
N/A
1.1.5
Add: Some equipment covered by these
requirements may also be required to comply with
applicable requirements in other standards
requirements may also be required to comply with
applicable requirements in other standards
N/A
1.2
Add references to ANSI, ASTM and UL standards
P
4.2.1
Add Note: In the U.S. the RATED SUPPLY
VOLTAGE for single-phase apparatus is
assumed to be 120 V or 120/240 V.
VOLTAGE for single-phase apparatus is
assumed to be 120 V or 120/240 V.
P
4.2.4
Revision to sub-clause a): Minimum audio output
is not less than 0.5 W per channel unless the
maximum audio output is less than 0.5 W per
channel.
is not less than 0.5 W per channel unless the
maximum audio output is less than 0.5 W per
channel.
N/A
4.2.4.1
Add: ―An apparatus with multiple modes of
operation, multiple signal input sources, or both,
is to be operated using each mode of operation or
signal input source separately, or in combination,
according to the manufacturer‘s instructions to
produce the maximum power input‖.
operation, multiple signal input sources, or both,
is to be operated using each mode of operation or
signal input source separately, or in combination,
according to the manufacturer‘s instructions to
produce the maximum power input‖.
Table 2: External supply sources are assumed to
be capable of delivering 30 A, unless otherwise
specified (no-load voltage and internal resistance
values in the Table are modified).
be capable of delivering 30 A, unless otherwise
specified (no-load voltage and internal resistance
values in the Table are modified).
P
4.3.4
Add: PTC thermistors may also comply with UL
1434.
1434.
N/A
Click on the first or last page to see other BDS 575 service manuals if exist.