Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 51 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
NO Norway
NO
Annex B Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Norway, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
"Apparatet skal tilkoples jordet stikkontakt"
N/A