Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 54 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
SE Sweden
Annex B
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Sweden, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
"Apparaten skall anslutas till
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Sweden, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
"Apparaten skall anslutas till
jordat uttag‖
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in the accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6
with an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5
kV (for performance of the test see N.2.1).
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in the accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6
with an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5
kV (for performance of the test see N.2.1).
N/A
Click on the first or last page to see other BDS 575 service manuals if exist.