Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 53 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
NO Norway
NO
- the Impulse test of 2.5kV is to be performed
before the Endurance Test in IEC 60384-14 in the
sequence of tests as described in IEC 60384-14.
before the Endurance Test in IEC 60384-14 in the
sequence of tests as described in IEC 60384-14.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals
or other reliable means, and for equipment which
is intended for connection to the building
installation wiring via an industrial plug and socket
-outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
equipment which is intended for connection to the
building installation wiring using screw terminals
or other reliable means, and for equipment which
is intended for connection to the building
installation wiring via an industrial plug and socket
-outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard.
N/A
Click on the first or last page to see other BDS 575 service manuals if exist.