IEC 60065, 6th edition : 1998
-
- Page 24 of 43 -
Order No.
200211175
Exception for low Stand-by current
< 0,7 mA (peak)
< 0,7 mA (peak)
N
14.6.5
Components bridging contacts of
mains switches comply with 14.1 a)
or 14.2.2
mains switches comply with 14.1 a)
or 14.2.2
Yes. See clause 14.1 and 14.2.
P
14.6.6.a.
Manually operated mechanical
switches (MOMS) separately
approved to IEC 61 058-1
switches (MOMS) separately
approved to IEC 61 058-1
Yes.
- Mains switch, certified by VDE,
- Mains relay, certified by SEMKO.
- Mains switch, certified by VDE,
- Mains relay, certified by SEMKO.
P
14.6.6.b.
Manually operated mechanical
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
Flame test for mains switches
N
14.6.7
Endurance test
N
14.6.8
Temperature rise in mains switch
N
14.6.9
Dielectric strength test
N
14.6.10
Surge current for mains switches
also controlling mains socket-outlets
also controlling mains socket-outlets
Measured surge current through mains switch, SW719
and mains relay, RLY451, RLY452: < 96Apeak.
- Rated surge current for SW719: 128A.
- Rated surge current for RLY451, RLY452: 120A. OK.
Mains relay, RLY453 controlling surge current for
switched mains socket outlet: 20A for 100W
- Rated surge current for RLY453: 120A OK.
and mains relay, RLY451, RLY452: < 96Apeak.
- Rated surge current for SW719: 128A.
- Rated surge current for RLY451, RLY452: 120A. OK.
Mains relay, RLY453 controlling surge current for
switched mains socket outlet: 20A for 100W
- Rated surge current for RLY453: 120A OK.
P
14.7
Safety interlocks
N
Safety interlocks to 2.8 of
IEC 60 950
IEC 60 950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to
be changed accidentally
be changed accidentally
No voltage selector
N
14.9
Motors
P
14.9.1
Endurance test on motors
No motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or
grease etc.
grease etc.
N
14.9.3
Protection against moving parts
No moving parts
N