AVR 7500 (serv.man9) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 28

Read Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 24 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
Exception for low Stand-by current 
< 0,7 mA (peak)   
 
14.6.5 
Components bridging contacts of 
mains switches comply with 14.1 a) 
or 14.2.2   
Yes. See clause 14.1 and 14.2. 
 
14.6.6.a. 
Manually operated mechanical 
switches (MOMS) separately 
approved to IEC 61 058-1   
Yes.   
- Mains switch, certified by VDE, 
- Mains relay, certified by SEMKO. 
14.6.6.b. 
Manually operated mechanical 
switch (MOMS) tested as part of the 
equipment complies with 14.6.7, 
14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1)   
 
 
Flame test for mains switches   
 
14.6.7 
Endurance test 
 
14.6.8 
Temperature rise in mains switch 
 
14.6.9 
Dielectric strength test 
 
14.6.10 
Surge current for mains switches 
also controlling mains socket-outlets 
Measured surge current through mains switch, SW719 
and mains relay, RLY451, RLY452: < 96Apeak. 
- Rated surge current for SW719: 128A.   
- Rated surge current for RLY451, RLY452: 120A.  OK. 
 
Mains relay, RLY453 controlling surge current for 
switched mains socket outlet: 20A for 100W 
- Rated surge current for RLY453: 120A           OK. 
14.7 
Safety interlocks 
 
 
 
Safety interlocks to 2.8 of 
IEC 60 950   
No safety interlock 
 
14.8 
Voltage setting devices 
 
 
 
Voltage setting device not likely to 
be changed accidentally   
No voltage selector 
 
14.9 
Motors 
 
 
14.9.1 
Endurance test on motors   
No motors 
 
 
Motor start test   
 
 
Dielectric strength test   
 
14.9.2 
Not adversely affected by oil or 
grease etc.   
 
14.9.3 
Protection against moving parts   
No moving parts 
Page of 54