AVR 7500 (serv.man9) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 26

Read Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 22 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
External clearance and creepage 
distances appropriate for the voltage 
across the device when opened   
 
14.5.1.1 
a) Thermal cut-outs separately 
approved   
Automatic: 
Manuf.: Seki Controls Co., Ltd. 
Type: ST-22 
Certified by: VDE 
 
b) Thermal cut-outs tested as part of 
the submission   
 
14.5.1.2 
a) Thermal links separately approved   
None 
 
b) Thermal links tested as part of the 
apparatus   
 
14.5.1.3 
Thermal devices resettable by 
soldering   
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit 
according to IEC 60 127   
See list below 
Circuit 
Manufacturer 
Dimen- 
Approved 
Marking of 
Marking 
Current 
diagram 
 
sions 
by 
rated current, 
close to 
through 
informa- 
 
 
 
pre-arcing time 
the com- 
the fuse   
tion 
 
 
 
and current 
ponent 
in normal 
Part No 
 
 
 
characteristic 
 
operation   
F451 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T1,25A L 250V 
T1,25A L 250V 
< 0,80 A 
F452 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T6,3A L 250V 
T6,3A L 250V 
< 2,36 A   
F453 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T500mA L 250V 
T500mA L 250V 
< 0,30 A 
F501, F502 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T1,6A L 250V 
T1,6A L 250V 
< 0,40 A 
F503, F504 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T3,15A L 250V 
T3,15A L 250V 
< 0,43 A 
F505, F506 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T3,15A L 250V 
T3,15A L 250V 
< 1,22 A 
F507, F508 
Littelfuse Triad Inc. 
5
× 20mm, 50T  S, VDE 
T1,25A L 250V 
T1,25A L 250V 
< 0,16 A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.5.2.2 
Correct marking of fuse-links 
adjacent to holder      
Correct marking applied close to the fuse, see table 
above. 
14.5.2.3 
Not possible to connect fuses in 
parallel      
No fuse holder so designed that fuse-links can be 
connected in parallel 
14.5.2.4 
Not possible to touch hazardous live 
parts when replacing fuse-links 
without the use of a tool     
No replacement of fuse possible by hand. 
 
14.5.3 
PTC-S thermistors comply with 
IEC 60 738   
No PTC’s 
Page of 54