AVR 7500 (serv.man9) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 27

Read Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 23 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
PTC-S devices (>15 W) category 
FV 1 or better   
 
14.5.4 
Other protective devises. 
Circuit protectors have adequate 
breaking capacity and their position 
is correctly marked   
No other protective devices 
14.6 
Switches 
 
 
 
Manually operated mechanical 
switch (MOMS) conductively 
connected to the mains
 
 
 
Part No 
Function 
Manufacturer 
Type 
Rated 
Marking 
 
All- 
One 
Name 
Trademark 
 
Surge 
 
pole 
pole 
 
 
 
 
 
current 
 
 
 
 
 
 
 
 
 
SW719 
 
Matsushita Electronic 
Y1 (ESB91511A) 
250 
128A 
RLY451, 
RLY452,
RLY453 
 
Original Electromecha. 
OEG 
SDT-S-112DMR 
250 
120A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.6.1 
Permanently connected equipment 
provided with an all-pole mains 
switch unless 5.4.2 is met   
Apparatus is not permanently connected 
 
14.6.2 
Manually operated mechanical 
switch (MOMS), required where 
power consumption > 15 W and/or 
peak voltage > 4 kV 
Yes. MOMS required. See table above. 
 
 
Switch readily accessible and not in 
mains cord   
Switch located on the front and readily accessible 
 
 
Exception for automatic switching   
 
 
Exception for continuous operation   
 
14.6.3 
Manually operated mechanical 
switch (MOMS): Switch indication / 
On position clearly discernible   
The display is illuminated. 
 
 
Indication by marking meets Cl. 5   
Yes 
 
 
Indication of the OFF position   
Off-position marked with “OFF” 
14.6.4 
Manually operated mechanical 
switch (MOMS) fitted. Is there a 
Stand-by mode      
Yes 
 
 
Stand-by mode clearly discernible      
LED indication 
Page of 54