Read Harman Kardon AVR 4550 EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 14 of 39 -
Order
No.
200245266
For class II constructions, test with
test probe 13 of IEC 61 032 (3N)
test probe 13 of IEC 61 032 (3N)
No access to hazardous live parts
P
Clearances to circuits exceeding
1000V a.c. or 1500V d.c.
1000V a.c. or 1500V d.c.
No voltages exceeding 1000V AC or 1500V DC.
N
9.1.2
No hazardous live shafts of knobs,
handles or levers
handles or levers
No live shafts, handles or levers
N
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with
1 mm x 20 mm test pin (10 N); test
probe 16 of IEC 61 032
1 mm x 20 mm test pin (10 N); test
probe 16 of IEC 61 032
Does not reach hazardous live parts
P
Terminal devices tested with
1 mm x 100 mm straight wire (1 N);
test probe D of IEC 61 032
1 mm x 100 mm straight wire (1 N);
test probe D of IEC 61 032
Does not reach hazardous live parts
P
9.1.5
Pre-set controls tested with
2.5 mm x 100 mm test pin (10 N);
test probe C of IEC 61 032
2.5 mm x 100 mm test pin (10 N);
test probe C of IEC 61 032
No preset controls
N
9.1.6
No shock hazard due to stored
charge on withdrawal of the mains
plug; voltage (V) after 2 s
charge on withdrawal of the mains
plug; voltage (V) after 2 s
Measured voltage after 2 sec.: < 4V peak.
P
If C is not greater than 0,1
µ
F no test
needed
N
9.1.7
Enclosure sufficiently resistant to
external force
external force
P
Test probe 11 of IEC 61 032 for 10 s
(50 N)
(50 N)
Test with test finger results in no hazard.
P
Test hook of fig. 4 for 10 s (20 N)
Test with test hook results in no hazard.
P
Conductive enclosures :
30 mm diameter test tool for 5 s (100
or 250 N)
30 mm diameter test tool for 5 s (100
or 250 N)
Test with 100N results in no damage.
P
9.2
No hazard 2s after removing a cover
by hand
by hand
No cover removable by hand
N
Click on the first or last page to see other AVR 4550 service manuals if exist.