AVR 4550 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 16

Read Harman Kardon AVR 4550 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 14 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
 
For class II constructions, test with 
test probe 13 of IEC 61 032 (3N) 
No access to hazardous live parts 
 
 
Clearances to circuits exceeding 
1000V a.c. or 1500V d.c.   
No voltages exceeding 1000V AC or 1500V DC. 
9.1.2 
No hazardous live shafts of knobs, 
handles or levers   
No live shafts, handles or levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin   
No access for the test pin. 
 
9.1.4 
Terminal devices tested with 
1 mm x 20 mm test pin (10 N); test 
probe 16 of IEC 61 032   
Does not reach hazardous live parts 
 
 
Terminal devices tested with 
1 mm x 100 mm straight wire (1 N); 
test probe D of IEC 61 032   
Does not reach hazardous live parts 
 
9.1.5 
Pre-set controls tested with 
2.5 mm x 100 mm test pin (10 N); 
test probe C of IEC 61 032   
No preset controls 
 
9.1.6 
No shock hazard due to stored 
charge on withdrawal of the mains 
plug; voltage (V) after 2 s      
Measured voltage after 2 sec.: < 4V peak. 
 
If C is not greater than 0,1 
µ
F no test 
needed  
 
9.1.7 
Enclosure sufficiently resistant to 
external force 
 
 
 
Test probe 11 of IEC 61 032 for 10 s 
(50 N)   
Test with test finger results in no hazard. 
 
 
Test hook of fig. 4 for 10 s (20 N)   
Test with test hook results in no hazard. 
 
Conductive enclosures : 
30 mm diameter test tool for 5 s (100 
or 250 N)      
Test with 100N results in no damage. 
9.2 
No hazard 2s after removing a cover 
by hand   
No cover removable by hand 
 