Read Harman Kardon AVR 4550 EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 13 of 39 -
Order
No.
200245266
Class II apparatus :
Double insulation between
conductors connected to accessible
parts and the mains
Double insulation between
conductors connected to accessible
parts and the mains
N
8.11
Detaching of wires
P
No undue reduction of creepage or
clearance distances if wires become
detached
clearance distances if wires become
detached
Primary wires connected with multi-contact-housing.
P
Vibration test carried out
Vibration test considered not necessary
N
8.12
Adequate cross-sectional area of
internal wiring to mains socket-
outlets
internal wiring to mains socket-
outlets
Socket outlet fuses provided
P
8.13
Adequate fastening of windows,
lenses, lamp covers etc. (push or
pull test 20 N for 10 s)
lenses, lamp covers etc. (push or
pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push
or pull test 50 N, for 10 s)
or pull test 50 N, for 10 s)
Covers adequately fastened with screws.
P
8.15
No risk of damage to the insulation
of internal wiring due to hot parts or
sharp edges
of internal wiring due to hot parts or
sharp edges
Wires safely anchored away from parts with high
temperature.
temperature.
P
8.16
Apparatus designed to be supplied
by special supply apparatus only.
by special supply apparatus only.
N
9
ELECTRIC SHOCK HAZARD
UNDER NORMAL OPERATING
CONDITIONS
UNDER NORMAL OPERATING
CONDITIONS
P
9.1.1
Touch current expressed as voltages
U1 and U2 in Annex D
U1 and U2 in Annex D
P
Location Measured
U1
V (peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
U1 Max 35V (peak)
U1 Max 1.0V (DC)
U2 Max 0.35V
(peak)
Mains pole 1 - RCA terminal
< 0,46 V
-
< 0,02 V
Pass
Mains pole 2 - RCA terminal
< 0,50 V
-
< 0,03 V
Pass
Discharge not exceeding 45
µ
C
No part or contact of a terminal with stored voltages
between 60V - 15kV
between 60V - 15kV
N
Energy of discharge not exceeding
350 mJ
350 mJ
No part or contact of a terminal with stored voltages
exceeding 15kV
exceeding 15kV
N
Test with test finger according to test
probe B of IEC 61 032 (20N)
probe B of IEC 61 032 (20N)
No access to hazardous live parts
P
Click on the first or last page to see other AVR 4550 service manuals if exist.