Read Harman Kardon AVR 4550 EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 39 -
Order
No.
200245266
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
2,25
A, P
=
439
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Marking of loudspeaker terminals
“
SPEAKERS (8
Ω)
:
SR, SL, FR, FL”
”SPEAKERS (8
Ω)
:
CTR, SBR/MILTI R, SBL/MILTI L”
U =
254,4
V
4 Ohm
8 Ohm
16 Ohm
Ohm
Left
right
left
right
left
right
left
right
Measured max. output voltage in Vp
F)
32,9
C) 32,7
S) 32,6
S/W) 32,5
S) 32,6
S/W) 32,5
F) 32,9
C) -
S) 32,6
S/W) 32,5
C) -
S) 32,6
S/W) 32,5
Measured max. output power in W
F)
67,6
C) 66,8
S) 66,4
S/W) 66,1
S) 66,4
S/W) 66,1
F) 67,6
C) -
S) 66,4
S/W) 66,1
C) -
S) 66,4
S/W) 66,1
Measured max. mains power in W
1027
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)