AVR 4550 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon AVR 4550 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 10 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
HEATING (continued) 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed *) 
Power TR, Q333 body 
54,6 
63,1 
PWB near Q333 
54,2 
61,9 
85 
Power TR, Q335 body 
60,8 
70,4 
Fan body (outer) 
29,8 
35,4 
60 
Main 
heat-sink 
41,1 43,6 - 
Appliance inlet body 
10,8 
14,3 
60 
Top enclosure above main heat-sink 
3,1 
3,3 
40 
Top enclosure above main transformer 
1,6 
1,6 
40 
Switch 
button 
0,2 0,3 50 
 
 
 
 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.   
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
 
 
 
 
 
 
7.2 
Softening temperature of insulating 
material supporting parts 
conductively connected to the mains 
carrying a current > 0,2 A at least 
150 
°
C  
No temperature measured during heating test and fault 
cond. tests requires this test (7.2) to be performed. 
Tested parts 
Temperature   
under normal 
operating con- 
ditions (°C) 
Temperature  
under fault 
conditions  
            (°C) 
Softening 
temperature 
            (°C) 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 49