AVR 360 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 27

Read Harman Kardon AVR 360 EMC - CB Certificate online

 
 
- Page 23 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15.4 
Devices forming a part of the mains plug  
 N/A 
15.4.1 
No undue strain on mains socket-outlets ……: 
The apparatus in not a  
device forming a part of the  
mains plug. 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs …………………………………….: 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) ……………………………………….: 
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ………………………….: 
Sheathed PVC cord  
complying with IEC 60227 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth ………………….: 
Class II apparatus 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment …………………………………: 
The cord is 0,75mm²,  
within the current rating 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength …………………………: 
No interconnecting cables  
comprising hazardous live  
conductors. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of 
IEC 60227-2): 
Cord complying with 16.1. 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions ……………………….: 
Cords have adequate  
cross-sectional areas to avoid  
temperature rise under normal  
and fault conditions. 
16.5 
Adequate strain relief on external flexible cords …: 
Cord clip wedged in the 
enclosure 
 
Not possible to push cord back into equipment …..: 
Checked by inspection 
 
Strain relief device unlikely to damage flexible cord 
No sharp edges 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
Class II apparatus 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use …………………………………: 
No sharp edges 
Page of 65