AVR 360 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 28

Read Harman Kardon AVR 360 EMC - CB Certificate online

 
 
- Page 24 of 44 - 
 
 
 
 
 Report 
No. 
129950 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1 ………………………: 
The apparatus is not a  
transportable musical  
instrument and amplifier 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord ……………………...: 
 
N/A 
 
17 
Electrical connections and mechanical fixings 
 
17.1 
Torque test to table 20  
 
 
- screws into metal: 5 times ………………………...: 
see appended table 17.1 
 
- screws into non-metallic material: 10 times ……..: 
No non-metallic material 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material ……………………………………..: 
No female threads in  
non-metallic materials 
N/A 
17.3 
Cover fixing screws: captive ………………………..: 
Captivity not necessary 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter ….:
Tested with screw with  
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A ………………………………………………..: 
Loosening is sufficiently 
prevented 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A ………………………………..: 
No contact pressure transmitted 
through insulating material. 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder …………………: 
No screw terminals. 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous ……………………………………...: 
No cover fixing devices  
other than screws 
N/A 
17.8 
Fixing devices for detachable legs or stands 
provided ……………………………:  
No detachable provided 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected ……………..: 
Connections complies,  
checked by inspection 
 
Page of 65
Display