Read Harman Kardon AVR 360 EMC - CB Certificate online
- Page 25 of 44 -
Report
No.
129950
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
Picture tube separately approved to IEC 61965 .:
No CRT in the equipment.
N/A
Picture tube separately approved to 18.1 ..…….….:
N/A
18.1
Picture tubes >16 cm intrinsically protected ….….:
N/A
Non-intrinsically protected tubes >16 cm used with
protective screen ..…………………………......:
protective screen ..…………………………......:
N/A
Protective film as part of implosion protection: edges
covered by enclosure ..…………………...…:
covered by enclosure ..…………………...…:
N/A
18.2
Intrinsically protected tubes: tests on 12 samples :
N/A
18.2.1
Samples subject to ageing: 6 samples ……………:
N/A
18.2.2
Samples subject to implosion test: 6 samples …:
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6 samples ..…………………………………….:
ball): 6 samples ..…………………………………….:
N/A
18.3
Non-intrinsically protected tubes tested to 18.3 ..:
N/A
19
Stability and mechanical hazards
Mass of the equipment exceeding 7 kg ..………….:
Weight: 13.6kg
⎯
Apparatus intended to be fastened in place –
suitable instructions …………………………….….:
suitable instructions …………………………….….:
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal …..:
Tested on a plane inclined at
an angle of 10°
an angle of 10°
P
19.2
100 N force applied vertically downwards ..…….:
100N force have no influence
on the stability
on the stability
P
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability ….…………………………….:
point of least stability ….…………………………….:
< 25 kg, < 1M
N/A
19.4
Edges or corners not hazardous ……………….....:
There is no hazardous edges
or corners when the
apparatus is operating in
normal position
or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1 …………………………:
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1 …………………………:
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate ………….:
Not intended for wall or ceiling
mounting
mounting
N/A
Click on the first or last page to see other AVR 360 service manuals if exist.