Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 1 of 3 -
Report No. 98388
ATTACHMENT: Tables to EN/IEC 60065 7
th
edition.
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location
Measured
U1V
(peak)
U1V
(peak)
Measured
U1
V (DC)
U1
V (DC)
Measured
U2
V (peak)
U2
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 – Antenna terminal
Pole 2 – Antenna terminal
Pole 2 – Antenna terminal
- -
0,04Vpeak
0,03Vpeak
0,03Vpeak
Pass
Pass
Pass
Pole 1 – other part or contact
Pole 2 – other part or contact
Pole 2 – other part or contact
- -
0,04Vpeak
0,03Vpeak
0,03Vpeak
Pass
Pass
Pass
Comments:
Vin = 253Vac, 60Hz
Only U2 have been recorded due to the use of linear transformers in power supply.