Report No.  98388 
 
 
13.3 – 13.4 
Clearances and Creepage distances 
Type  
of  
Insulation 
Position/ 
Location 
Position/ 
Location 
Working 
Voltage (V) 
Clearance 
13.3.2 
Creepage dist  
13.4 
Comm
Up 
Urms
Req. 
Measu. 
Req. 
Measu. 
Basic 
Live 
Neutral 
326 
230 
2,0 mm
3,6 mm
2,5 mm 
3,6 mm 
1) 
Basic 
Live 
Neutral 
326 
230 
2,0 mm
3,6 mm
2,5 mm 
3,6 mm 
2) 
Reinforce
 
Primary 
Secondary 
354 
250 
4,0 mm
5,3 mm
5,0 mm 
5,3 mm 
3) 
Reinforce 
Primary 
Chassis 
326 
230 
4,0 mm
5,5 mm
5,0 mm 
5,5 mm 
4) 
Reinforce
 
Primary 
Chassis *) 
326 
230 
4,0 mm
6,0 mm
5,0 mm 
>6,0 mm  5) 
Reinforce 
Primary 
Chassis 
326 
230 
4,0 mm
7,0 mm
5,0 mm 
7,0 mm 
6) 
Reinforce
 
Primary 
Chassis 
326 
230 
4,0 mm
5,6 mm
5,0 mm 
5,6 mm 
7) 
Reinforce 
Primary 
Secondary 
375 
265 
4,0 mm
6,5 mm
5,6 mm 
6,5 mm 
8) 
*) 2N force applied 
Note: U in Volt, Clearances/Creepage Distances in mm, Comm.=Comment 
Comments:  1) Measured on PCB before mains fuse (F901). 
2) Measured on TRANS PCB after 6,3A mains fuse between CN91 connected copper traces 
    (Part of directly connected to the mains). 
3) Measured on main pcb from pri. trace to near secondary trace. 
4) Measured between pri. trace for socket-outlet and near metal chassis (back cover) 
5) Measured between primary solder pin and embossed metal chassis (bottom) 
6) Measured between primary part of switch and near metal chassis (back cover) 
7) Measured on main pcb from CN91 connected live trace to ET01 trace 
8) Measured on main pcb from socket-outlet trace and near secondary trace. 
 