AVR 355 (serv.man5) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon AVR 355 (serv.man5) EMC - CB Certificate online

 
 
- Page 5 of 9 - 
 
 
www.nemko.com
 
Report No. 
108568 
 
 
 
14.5.1.2 
a) Thermal links separately approved 
Thermal links in main and 
sub transformer are 
separately approved 
component. See list of  
critical components.
 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No thermal devices 
re-settable by sildering
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are approved 
components according to 
IEC 60127. 
See list of critical components
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder   :
The following marking 
applied; 
F901: T6.3A L 250V 
F902; T2.5A L 250V 
F110, F111: T3.15A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ......... : 
No possible to connect  
fuses in parallel.
 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .. : 
No replacement of fuses 
possible by hand.
 
Page of 14