Read Harman Kardon AVR 355 (serv.man5) EMC - CB Certificate online
- Page 5 of 9 -
www.nemko.com
Report No.
108568
14.5.1.2
a) Thermal links separately approved
Thermal links in main and
sub transformer are
separately approved
component. See list of
critical components.
sub transformer are
separately approved
component. See list of
critical components.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable by sildering
re-settable by sildering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved
components according to
IEC 60127.
See list of critical components
components according to
IEC 60127.
See list of critical components
P
14.5.2.2
Correct marking of fuse-links adjacent to holder :
The following marking
applied;
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T3.15A L 250V
applied;
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T3.15A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ......... :
No possible to connect
fuses in parallel.
fuses in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .. :
replacing fuse-links without the use of a tool .. :
No replacement of fuses
possible by hand.
possible by hand.
P
Click on the first or last page to see other AVR 355 (serv.man5) service manuals if exist.