Read Harman Kardon AVR 355 (serv.man5) EMC - CB Certificate online
- Page 6 of 9 -
www.nemko.com
Report No.
108568
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
253V or 198V
—
Ambient temperature (
o
C) ................................... :
23 - 26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Limit dT (K)
*), D707 (AC to -), S-c;
Normal operated, Input current stabilised at 2.54A,
F111 opened, No hazard (Tested time: 30 min).
Normal operated, Input current stabilised at 2.54A,
F111 opened, No hazard (Tested time: 30 min).
N/A N/A
**), D707 (AC to -), S-c;
Normal operated, Input current stabilised at 2.31A.
F111 opened, No hazard (Tested time: 30 min).
Normal operated, Input current stabilised at 2.31A.
F111 opened, No hazard (Tested time: 30 min).
N/A N/A
*), D707 (AC to +), S-c;
Normal operated, Input current stabilised at 2.53A,
F110 opened, No hazard (Tested time: 10 min).
Normal operated, Input current stabilised at 2.53A,
F110 opened, No hazard (Tested time: 10 min).
N/A N/A
**), D707 (AC to +), S-c;
Normal operated, Input current stabilised at 2.32A,
F110 opened, No hazard (Tested time: 10 min).
Normal operated, Input current stabilised at 2.32A,
F110 opened, No hazard (Tested time: 10 min).
N/A N/A
*), C129, S-c;
Normal operated, Input current stabilised at 2,46A,
F110 and F111 opened, No hazard (Tested time: 20 min).
Normal operated, Input current stabilised at 2,46A,
F110 and F111 opened, No hazard (Tested time: 20 min).
N/A N/A
**), C129, S-c;
Normal operated, Input current stabilised at 2,26A,
F110 and F111 opened, No hazard (Tested time: 20 min).
Normal operated, Input current stabilised at 2,26A,
F110 and F111 opened, No hazard (Tested time: 20 min).
N/A N/A
*)
Tested
voltage
253V
**)
Tested
voltage
198V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded