Read Harman Kardon AVR 355 (serv.man5) EMC - CB Certificate online
- Page 3 of 9 -
www.nemko.com
Report No.
108568
Test case verdicts
Test case does not apply to the test object :
N/A
Test item does meet the requirement ........ :
P(ass)
Test item does not meet the requirement .. :
F(ail)
Testing
Date of receipt of test item ......................... :
June 2008
Date(s) of performance of test ................... :
June 2008
General remarks
”This report is not valid as a CB Test Report unless appended by an approved CB Testing
Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02”.
Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02”.
The test result presented in this report relate only to the object(s) tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
”(see attachment #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
Summary of testing:
This amendment test report, 108568 is covering the variation for components as follows,
A. Secondary fuses (P/N: F110 and F111);
Changed electrical rating from T2.5A L 250V to T3.15A L 250V.
B. Secondary rectifier diode (not listed component in CCL);
Changed type and location from two pieces of monolithic diodes (P/N: D122 and D123) in TRANS
pcb to one piece of bridge diode (P/N: D707) with exclusive use small pcb on bottom chassis.
This amendment test report “108568” must always be presented together with the main test report “98388”.
Click on the first or last page to see other AVR 355 (serv.man5) service manuals if exist.