AVR 240 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 48

Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online

 
 
- Page 6 of 7 - 
 
 
www.nemko.com
 
Report No.  65654 
 
 
13.3 - 13.4
 
Clearances and Creepage distances
 P 
Type of 
Insulation 
Position/ 
Location 
Position/ 
Location 
Working  
Voltage 
Clearance 
13.3.2 
Creepage dist. 
13.4
 
Comm. 
 1  2 
Up 
Urms
Req. 
Measu.
Req. 
Measu. 
 
Basic Live  Neutral  326V 
230V 
2,0mm 
4,0mm 2,5mm 
4,0mm 
1) 
Reinforce Primary 
Chassis 
326V  230V  4,0mm  8,0mm 5,0mm > 
8,0mm 2) 
Reinforce Primary 
C708 
*) 
379V 268V 4,0mm 7,8mm 5,6mm > 
7,8mm 
3) 
Reinforce Primary 
Chassis 
326V  230V  4,0mm  7,3mm 5,0mm > 
7,3mm 4) 
Reinforce Primary 
Chassis 
326V  230V  4,0mm  6,8mm 5,0mm 6,8mm  5) 
Reinforce Primary 
Secondary  379V 268V 4,0mm 6,0mm 5,6mm 6,0mm  6) 
 
 
 
 
 
 
 
 
 
 
*) 2N force applied 
Note: U in Volt, Clearances/Creepage Distances in mm, Comm. = Comment 
Comments: 
1)  Measured on PCB before mains fuse (F907). 
2)  Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3)  Measured between socket outlet terminal and near C708 secondary E. capacitor. 
4)  Measured between main pcb primary solder pin and metal bottom chassis. 
5)  Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace. 
6)  Measured on main pcb from pri. pcb trace to near secondary pcb trace. 
 
 
 
 
Page of 49