FAULT CONDITIONS TESTS
 
 
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V 
— 
 
Ambient temperature (
o
C) ...................................... :
24 -26 °C 
— 
Comp. 
No. 
Location  Fault 
Test V 
Test  
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D104 
A - C 
S-c 
253 
30 min 
F907 
1,85 A 
Normal operating. 
Input current stabilised at 1,78A. 
R106
 
opened.  No hazard. 
C122 
S-c 
253 
4 hr 
F907 
2,18 A 
FL display off immediately. 
Input current stabilised at 1,94A. 
R101 damaged. 
Main transformer primary winding 
heated-up to 130K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
Q104 
C - E 
S-c 
253 
1 hr 
F907 
1,84 A 
Normal operating. 
Input current stabilised at 1,80A. 
No component damaged. 
No hazard. 
Q104 
B - C 
S-c 
253 
4 hr 
F907 
2,15 A 
FL display off immediately. 
Input current stabilised at 1,97A. 
R101, Q104, D101, D102 
damaged. 
Main transformer primary winding 
heated-up to 123K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
C119 
S-c 
253 
3 hr 
F907 
2,00 A 
FL display off immediately. 
Input current stabilised at 1,96A. 
Q104 damaged. 
Main transformer primary winding 
heated-up to 116K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
C117 
S-c 
253 
20 min 
F907 
1,79 A 
Normal operating. 
Input current stabilised at 1,79A. 
No component damaged. 
No hazard. 
D991 
AC - + 
S-c 
207 
10 min 
F907 
F903 
F904 
- Normal 
operating. 
Input current stabilised at 1,64A. 
F904 opened.  No hazard. 
(Repeated test three times with the 
same result) 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
         
         
 