AVR 240 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 45

Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online

 
 
- Page 3 of 7 - 
 
 
www.nemko.com
 
Report No.  65654 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Location  Fault 
Test V 
Test  
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
D991 
AC - + 
S-c 
253 
10 min 
F907 
F903 
F904 
- Normal 
operating. 
Input current stabilised at 1,76A. 
F904 opened.  No hazard. 
(Repeated test three times with the 
same result) 
C902 -  S-c 207 10 
min 
F907 
F903 
F904 
Front, Surr Back channels signal 
output off immediately. 
Input current stabilised at 0,85 A. 
F903, F904 opened. 
No hazard. 
(Repeated test three times with the 
same result) 
C902 -  S-c 253 10 
min 
F907 
F903 
F904 
Front, Surr Back channels signal 
output off immediately. 
Input current stabilised at 0,89 A. 
F903, F904 opened. 
No hazard. 
(Repeated test three times with the 
same result) 
D992 
AC - + 
S-c 
207 
10 min 
F907 
F905 
F906 
- Normal 
operating. 
Input current stabilised at 1,70A. 
F906 opened. 
No hazard. 
D992 
AC - + 
S-c 
253 
10 min 
F907 
F905 
F906 
- Normal 
operating. 
Input current stabilised at 1,78A. 
F906 opened. 
No hazard. 
C915 -  S-c 253 10 
min 
F907 
F905 
F906 
Center, Surround channels signal 
output off immediately. 
Input current stabilised at 1,21A. 
F905, F906 opened. 
No hazard. 
Q803 
C - E 
S-c 
207 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
No hazard. 
Q803 
C - E 
S-c 
253 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
Q804 shorted. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 