Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online
- Page 3 of 7 -
www.nemko.com
Report No. 65654
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
D991
AC - +
S-c
253
10 min
F907
F903
F904
F903
F904
- Normal
operating.
Input current stabilised at 1,76A.
F904 opened. No hazard.
(Repeated test three times with the
same result)
F904 opened. No hazard.
(Repeated test three times with the
same result)
C902 - S-c 207 10
min
F907
F903
F904
F903
F904
-
Front, Surr Back channels signal
output off immediately.
Input current stabilised at 0,85 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
output off immediately.
Input current stabilised at 0,85 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
C902 - S-c 253 10
min
F907
F903
F904
F903
F904
-
Front, Surr Back channels signal
output off immediately.
Input current stabilised at 0,89 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
output off immediately.
Input current stabilised at 0,89 A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
D992
AC - +
S-c
207
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,70A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
AC - +
S-c
253
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,78A.
F906 opened.
No hazard.
F906 opened.
No hazard.
C915 - S-c 253 10
min
F907
F905
F906
F905
F906
-
Center, Surround channels signal
output off immediately.
Input current stabilised at 1,21A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 1,21A.
F905, F906 opened.
No hazard.
Q803
C - E
S-c
207
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Q803
C - E
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 240 (serv.man13) service manuals if exist.