Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online
- Page 28 of 33 -
www.nemko.com
Report No. 65654
7.2
TABLE: softening temperature of thermoplastics
N
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500V No
Between parts separated by double or reinforced insulation
3000V No
TRF No: IEC/EN 60065F