Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online
- Page 26 of 33 -
www.nemko.com
Report No. 65654
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is less
than 2,7W.
the power consumption is less
than 2,7W.
P
Position of the functional switch (W) ...................... :
—
Operating conditions
Standby mode:
Un (V)
In (A)
Pn (W)
Pout (W)
207 0,012 2,0 —
230 0,012 2,3 —
253 0,012 2,7 —
Measured at maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
253
3,80
774
2 x 67,6 W
(F)
1 x 67,4 W
(C)
2 x 62,6 W
(S)
2 x 71,4 W
(S/B)
Measured at 1/8 of maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
207
1,71
262
2 x 8,5 W
(F)
1 x 8,4 W
(C)
2 x 7,8 W
(S)
2 x 8,9 W
(S/B)
230
1,75
297
2 x 8,5 W
(F)
1 x 8,4 W
(C)
2 x 7,8 W
(S)
2 x 8,9 W
(S/B)
253
1,79
334
2 x 8,5 W
(F)
1 x 8,4 W
(C)
2 x 7,8 W
(S)
2 x 8,9 W
(S/B)
Loudspeaker impedance (Ω) ....................
8 Ohm
—
Several loudspeaker systems
Right and Left for Front,
Only one for Center,
Right and Left for Surround,
Right and Left for Surr Back channels
Only one for Center,
Right and Left for Surround,
Right and Left for Surr Back channels
—
Marking of loudspeaker terminals
SPEAKERS ( 8Ω ): FRONT, CENTER,
SURROUND, SURR BACK
—
TRF No: IEC/EN 60065F