Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online
- Page 27 of 33 -
www.nemko.com
Report No. 65654
Monitored point:
dT (K)
at 207V
dT (K)
at 253V
Limit dT (K)
*)
Main transformer core
53,6
57,5
85
Sub transformer core
37,4
45,0
85
Diode, D991 body
61,5
63,9
-
PWB near D991
61,9
63,0
85
TR, Q803 body
50,5
59,5
-
TR, Q804 body
32,5
38,9
-
PWB near Q804
48,1
56,0
85
E. Capacitor, C909 body
33,4
36,8
-
E. Capacitor, C916 body
25,9
29,0
-
Resistor, R810 body
44,2
50,3
-
Main heat-sink
49,2
59,3
-
Fan body (on heat-sink)
31,8
38,3
60
Power cord bushing
26,6
28,6
60
Top enclosure above main transformer
30,3
35,0
65 **)
Top enclosure above main heat-sink
27,8
33,5
65 **)
*) Temperature rise limits for Singapore is 10K less
**) Directly covering part for heat-sink and transformer. The top cover is supplied with ventilation openings
covering most of the top cover. This indicate emission of heat from internal parts and the opening area is
therefore not likely to be touched during normal use.
covering most of the top cover. This indicate emission of heat from internal parts and the opening area is
therefore not likely to be touched during normal use.
Winding temperature rise measurements
207V
253V
—
Ambient temperature t1 (
o
C) :
24,5
24,5
—
Ambient temperature t2 (
o
C) :
24,9
23,5
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Main transf. pr. winding (207V)
1,807 2,288 68,5 85
E
Sub transf. pr. winding (207V)
2747 3235 45,6 85
E
Main transf. pr. winding (253V)
1,807 2,305 72,4 85
E
Sub transf. pr. winding (253V)
2747 3347 57,6 85
E
TRF No: IEC/EN 60065F