Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.3    Radiated radio-frequency electromagnetic field 
 
RESULT :                                                                                                              Pass 
 
5.3.1 Measurement Procedure 
The immunity against radio-frequency electromagnetic  fields was tested in accordance to 
EN55020:1994+A11:1996+A12,A13,A14:1999.  The test set-up was make according to 
EN61000-4-3: 1996+A1: 1998+A2:2001 in semi-anechoic chamber. The EUT has bees 
placed in center of a wooden turntable. The height of this table was 0.8m. The field strength 
was monitored by an isotropic sensor during the complete test. 
The isotropic sensor was located beside the equipment. The antenna has been orientated for 
both horizontal and vertical polarization. The distance between antenna the equipment under 
testing was at least 3m. The tests have been performed with the antenna facing each of the 
four side of the EUT. 
 
Radio-frequency electromagnetic field. Keyed carrier. 
 
Severity level 
: 2 
Field strength 
: 3V/m 
Frequency range 
: 900㎒  ±5㎒ 
Duty cycle 
: 50% 
Rep. frequency 
: 200 Hz 
Performance criterion 
: A 
 