Read Harman Kardon AVR 235 (serv.man2) EMC - CB Certificate online
DIGITAL EMC CO., LTD.
Page 12 of 19
Test Report
No.:
DR50120306G
5.4 Electrical fast transient / burst
RESULT : Pass
5.4.1 Measurement Procedure
The immunity against fast transients was tested in accordance to EN55020:1994 +A11:1996
+ A12,A13,A14:1999. on all lines which length may exceed 3m according to the
manufacturers specification. Test set-up with capacitive clamp and fast transient noise
generator was according to EN61000-4-4: 1995+A1:2001.
The EUT has been placed on a wooden table 0.8m above the reference ground plane.
The reference ground plane exceeded the projected geometry of the EUT and the capacitive
clamp by more than 20cm. The clamp has placed directly on the reference ground plane.
The un-used signal connector of the clamp has been terminated with a 50Ω resistor.
The distance between the EUT and all other conductive structures. Except the ground plane
beneath the EUT was more than 0.5m. The distance between clamp and EUT was about 30cm.
beneath the EUT was more than 0.5m. The distance between clamp and EUT was about 30cm.
Severity level
: 2 (AC Power port)
Test voltage
: 0.5, 1 (kV)
Polarity :
Negative/
positive
Repetition frequency
: 5㎑
Performance criterion
: B
5.4.2 List of Test and Measurement Instruments
Electrical fast transient / burst
Name of
Instrument
Model No
Serial No
Manufacturer
Next Cal.
Date
BEST EMC
BEST EMCV2.7 200122-043SC
SCHAFFNER
2003.09
PERSONAL
COMPUTER
Emachines/AC
50035 045 00056
COMPUTOWN
N/A
EFT Clamp
CDN8014
17332
SCHAFFNER
N/A
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080