AVR 235 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 108

Read Harman Kardon AVR 235 (serv.man2) EMC - CB Certificate online

       
DIGITAL EMC CO., LTD.      
Page 12 of 19 
Test Report   
                                                        No.: 
DR50120306G
 
 
 
5.4 Electrical fast transient / burst 
 
RESULT :                                                                                                              Pass 
 
5.4.1 Measurement Procedure 
 
The immunity against fast transients was tested in accordance to EN55020:1994 +A11:1996 
+ A12,A13,A14:1999.
 on all lines which length may exceed 3m according to the 
manufacturers specification.  Test set-up with capacitive clamp and fast transient noise 
generator was according to EN61000-4-4: 1995+A1:2001. 
The EUT has been placed on a wooden table 0.8m above the reference ground plane. 
The reference ground plane exceeded the projected geometry of the EUT and the capacitive 
clamp by more than 20cm. The clamp has placed directly on the reference ground plane.   
The un-used signal connector of the clamp has been terminated with a 50Ω resistor. 
The distance between the EUT and all other conductive structures. Except the ground plane 
beneath the EUT was more than 0.5m. The distance between clamp and EUT was about 30cm. 
 
 
Severity level 
:  2 (AC Power port) 
Test voltage 
:  0.5, 1 (kV) 
Polarity : 
Negative/ 
positive 
Repetition  frequency 
:  5㎑ 
Performance criterion 
:  B 
 
5.4.2 List of Test and Measurement Instruments 
 
Electrical fast transient / burst 
Name of 
Instrument 
Model No 
Serial No 
Manufacturer 
Next Cal. 
Date 
BEST EMC 
BEST EMCV2.7 200122-043SC 
SCHAFFNER 
2003.09 
PERSONAL 
COMPUTER 
Emachines/AC 
50035 045 00056 
COMPUTOWN 
N/A 
EFT Clamp 
CDN8014 
17332 
SCHAFFNER 
N/A 
 
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
 
Page of 115
Display