Read Harman Kardon AVR 235 (serv.man2) EMC - CB Certificate online
DIGITAL EMC CO., LTD.
Page 11 of 19
Test Report
No.:
DR50120306G
5.3.2 List of Test and Measurement Instruments
Radiated radio-frequency electromagnetic field
Name of
Instrument
Type Serial
No
Manufacturer
Next Cal.
Date
Control computer
Pentium 750MHz
N/A
SAMSUNG
-
Software TEMTO-RS Ver.4.3en
TSJ
-
Electric Field Sensor
(~5KHz,~800V/m)
HI-6005 107823
Holaday
2004.01
Signal
Generator(3.3GHz)
SML03
100647
Rohde &y Schwarz
2004.03
Power Meter
NRVD
100403
Rohde &y Schwarz
2004.03
RF Switch Matrix
(~12GHz,500W)
RFM-S3A2CIL 2075
TSJ
2004.05
Antenna(75M~1.5G
Hz,1kW)
VULP9118 754
Schwarzbeck 2004.01
Horn Antenna
(0.8G~5GHz)
(0.8G~5GHz)
BBHA9120A 322
Schwarzbeck 2004.03
RF Power Amplifier
(~1GHz,250W)
CMC250 FO44-0620
IFI
2004.04
RF Power Amplifier
(1-3GHz,25W)
5055R 1007
Ophir
RF 2004.04
5.3.3 TEST RESULT
1) Test Data:
June 09, 2003
Temperature: 28 ℃
Temperature: 28 ℃
Humidity: 59 %
Barometric: 990 mbar
Barometric: 990 mbar
2) Uncertainty (95%,Confidence level, k=2.28) : ±1.6dB
3) Result
Result
Position
Horizontal Vertical
Remark
Front Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Right Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Left Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Back Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Table 2 : Radiated radio-frequency electromagnetic field
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080