Read Harman Kardon AVR 141 (serv.man3) EMC - CB Certificate online
- Page 6 of 10 -
Report
No.
123035
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Annex ZA
Cont.
P
GROUP DIFFERENCES FOR AMENDMENT 1
COMMON MODIFICATIONS
COMMON MODIFICATIONS
N/A
5.1 i)
in EN 60065:2002
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
N/A
5.4.1
Add the following indent:
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
N/A
6.1
6.1
6.1
in EN 60065:2002
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount
of radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm2 or by measuring equipment of
other types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service controls
adjusted so as to give maximum radiation whilst maintaining the equipment operative
for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the
equipment are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall
not exceed 1
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount
of radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm2 or by measuring equipment of
other types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service controls
adjusted so as to give maximum radiation whilst maintaining the equipment operative
for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the
equipment are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall
not exceed 1
μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background
level.
NOTE These values appear in Directive 96/29/Euratom.
NOTE These values appear in Directive 96/29/Euratom.
N/A